INPUT:
Voltage range Note.1 85-264VAC 120-370VDC
AC current 1.3A/115VAC 0.8A/230VAC
Frequency range 47-63Hz
Inrush current (max) Cold start: 30A/115VAC 60A/230VAC
OUTPUT:
DC voltage (V) 12V 24V 48V
Efficiency 82% 85% 86%
Rated Current (A) 7.5A 4A 2A
Rated power(W) 90W 96W 96W
Voltage ADJ.range 12-15V 24-30V 48-56V
Ripple & noise(max ) Note.3 120mVp-p 150mVp-p 200mVp-p
Voltage tolerange Note.4 ±1% ±1% ±1%
Line regulation ±1% ±1% ±1%
Load regulation ±1% ±1% ±1%
Setup, rise time Note.5 3000ms 50ms/230VAC 3000ms 50ms/115VAC(at full load)
Hold up time 50ms/230VAC 20ms/115VAC(at full load)
Status indicator Green LED
Note:
1.Derating maybe needed under low input voltages,please check the derating curve for more detail.
2.All parameters NOT specially mentioned are measured at 230VAC input,rated load and 25℃ of
ambient temperature.
3.Ripple & noise are measured at 20MHZ of bandwidth by using a “12”twisted pair-wire terminated
with a 0.1uf & 47uf parallel capacitor.
4.Tolerance:includes set up tolerance,line regulation and load regulation.
5.Length of set up time is measured at cold first statr.Turning ON/OFF the power supply may lead to
increase of the set up time
6.The ambient temperature derating of 3.5℃ /1000m with fanless models and of 5℃ /1000m with fan
models for operating altitude higher than 2000m(6500ft)