INPUT:
Voltage range 85-264VAC 120-370VDC
AC current 1.8A/115VAC 1A/230VAC
Frequency range 47-63Hz
Inrush current (max) Cold start: 30A/115VAC 60A/230VAC
OUTPUT:
DC voltage (V) 5V 12V 24V 48V
Efficiency 78% 86% 88% 88%
Rated Current (A) 10A 5A 2.5A 1.25A
Rated power(W) 50W 60W 60W 60W
Voltage ADJ.range 5-6V 12-15V 24-30V 48-56V
Ripple & noise(max ) Note.2 80mVp-p 120mVp-p 150mVp-p 200mVp-p
Voltage tolerange Note.3 ±2% ±1% ±1% ±1%
Line regulation ±1% ±1% ±1% ±1%
Load regulation ±1.5% ±1% ±1% ±1%
Setup, rise time Note.4 500ms 30ms/230VAC 500ms 30ms/115VAC(at full load)
Hold up time 50ms/230VAC 20ms/115VAC(at full load)
Status indicator Green LED
Note:
100 100
1.All parameters NOT specially mentioned are measured at 230VAC input,rated load and 25℃ of
ambient temperature.
2.Ripple & noise are measured at 20MHZ of bandwidth by using a “12”twisted pair-wire terminated
with a 0.1uf & 47uf parallel capacitor.
3.Tolerance:includes set up tolerance,line regulation and load regulation.
4.Length of set up time is measured at cold first statr.Turning ON/OFF the power supply may lead to
increase of the set up time
5.The ambient temperature derating of 3.5℃ /1000m with fanless models and of 5℃ /1000m with fan
models for operating altitude higher than 2000m(6500ft)