Namfare chuyên sửa chữa máy phay CNC của hãng LNC các đời cũ tới mới. Chúng tôi đã sửa chữa các máy lỗi EMG, lỗi tín hiệu I/O, lỗi sập nguồn, lỗi báo khóa trục, báo lỗi drive và lỗi spindle. Với kinh nghiệm nhiều năm chúng tôi tự tin sửa chữa các loại máy chạy hệ điều khiển của China, Đài Loan và các hãng GSK, Weihong, Leadshine, Syntec đủ loại.
OP 1001:X SERVO ALARM
OP 1002:Y SERVO ALARM
OP 1003:Z SERVO ALARM
OP 1004:4TH SERVO ALARM
OP 1100:5TH SERVO ALARM
OP 1101:6TH SERVO ALARM
(1) Alarm message from SERVO driver.
(2) Please check ERROR message from the SERVO driver to know the cause.
(3) Please re-booting.
OP 1013:DETACH/ATTACH X-AXIS AS MOVING
OP 1014:DETACH/ATTACH Y-AXIS AS MOVING
OP 1015:DETACH/ATTACH Z-AXIS AS MOVING
OP 1016:DETACH/ATTACH 4TH-AXIS AS MOVING
OP 1024:DETACH/ATTACH 5TH-AXIS AS MOVING
OP 1025:DETACH/ATTACH 6TH-AXIS AS MOVING
(1) Move is not allowed when switching.
OP 1017:LNC SYSTEM EXPIRED
(1) Please contact with distributor or machine makers.
OP 1018:DESIRED MACRO VARIABLES NOT EXIST.
(1) Check Macro variables.
LNC-M515i
SYSTEM ALARM (Alarm)and WARNING(Warning)
212 LNC Technology Co., Ltd.
OP 1019:DESIRED MACRO VARIABLES OVER RANGE
(1) Check Macro variable value.
OP 1020:OVER MLC TRAVEL LIMIT
(1) Check each axis hardware travel limit.
OP 1021:GEAR SIGNAL ERROR
(1) Check if gear is correct.
OP 1027:HSP LONG, NEED TO CONTACT WITH SYSTEM PROVIDER.
(1) Please contact with distributor or machine makers
OP 1029:X AXIS OVER MLC TRAVEL LIMIT (+)
OP 1030:X AXIS OVER MLC TRAVEL LIMIT (-)
OP 1031:Y AXIS OVER MLC TRAVEL LIMIT (+)
OP 1032:Y AXIS OVER MLC TRAVEL LIMIT (-)
OP 1033:Z AXIS OVER MLC TRAVEL LIMIT (+)
OP 1034:Z AXIS OVER MLC TRAVEL LIMIT (-)
OP 1035:4TH AXIS OVER MLC TRAVEL LIMIT (+)
OP 1036:4TH AXIS OVER MLC TRAVEL LIMIT (-)
OP 1037:5TH AXIS OVER MLC TRAVEL LIMIT (+)
OP 1038:5TH AXIS OVER MLC TRAVEL LIMIT (-)
OP 1039:6TH AXIS OVER MLC TRAVEL LIMIT (+)
OP 1040:6TH AXIS OVER MLC TRAVEL LIMIT (-)
(1) Press rest to reboot system
LNC-M515i
SYSTEM ALARM (Alarm)and WARNING(Warning)
LNC Technology Co., Ltd. 213
OP 6001:X AXIS OVER MLC TRAVEL LIMIT (+)
OP 6002:X AXIS OVER MLC TRAVEL LIMIT (-)
OP 6003:Y AXIS OVER MLC TRAVEL LIMIT (+)
OP 6004:Y AXIS OVER MLC TRAVEL LIMIT (-)
OP 6005:Z AXIS OVER MLC TRAVEL LIMIT (+)
OP 6006:Z AXIS OVER MLC TRAVEL LIMIT (-)
OP 6007:4TH AXIS OVER MLC TRAVEL LIMIT (+)
OP 6008:4TH AXIS OVER MLC TRAVEL LIMIT (-)
OP 6009:5TH AXIS OVER MLC TRAVEL LIMIT (+)
OP 6010:5TH AXIS OVER MLC TRAVEL LIMIT (-)
OP 6011:6TH AXIS OVER MLC TRAVEL LIMIT (+)
OP 6012:6TH AXIS OVER MLC TRAVEL LIMIT (-)
(1) Check each axis hardware travel limit.
LNC-M515i
SYSTEM ALARM (Alarm)and WARNING(Warning)
214 LNC Technology Co., Ltd.
6.2 INT INTERPRETATION ALARM
INT 3001:NO SUCH TOKEN
(1) Part program enter data has invalid symbols or characters.
(2) Modify program error.
(3) Press RESET to clear the wrong warning message.
INT 3002:GRAMMAR ERROR
(1) Part program enter data has invalid symbols or characters.
(2) Modify program error.
(3) Press RESET to clear the wrong warning message.
INT 3003:OUT OF NODE MEMORY
(1) MACRO grammar has too complicate showing program such as too many brackets.
(2) Simplify complexity degree or make it to be 2 blocks.
(3) Press RESET to clear the wrong warning message.
INT 3004:EXECUTE NODE ERROR
(1) System executes mathematics calculation that is not allow to execute
(2) Press RESET to clear the wrong warning message.
INT 3005:FUNCTION ERROR
(1) System executes invalid function that is not allow to execute.(Won’t happen under normal
system condition.)
(2) System error, please contact the supplier.
INT 3006:DIVIDED BY 0
(1) MACRO is divided by 0.
(2) Modify numerator of the division. Must NOT be 0.
(3) Press RESET to clear the wrong warning message.
INT 3007:VARIABLE OVER RANGE
(1) One/some of local variables, common variables and global variables are out of range.
(2) Modify variable numbers that are out of their number range.
(3) Press RESET to clear the wrong warning message.
LNC-M515i
SYSTEM ALARM (Alarm)and WARNING(Warning)
LNC Technology Co., Ltd. 215
INT 3008:MACRO DOMAIN ERROR
(1) MACRO function domain error. If square (SQRT) argument is negative or ATAN arguments
are two zeros.
(2) Modify domain.
(3) Press RESET to clear the wrong warning message.
INT 3010:NOT ALLOWABLE DECIMAL POINT
(1) NC address has not allowable decimal point.
(2) Modify decimal point in NC address.
INT 3011:WORD DATA OVER RANGE
(1) NC address word data is out of range.
(2) Modify word data in NC address.
(3) Press RESET to clear wrong warning message.
INT 3012:MACRO ILLEGAL MACRO PARAMATER INPUT(G、L、N、O、P)
(1) Illegal arguments(G,L,N,O,P)in MACRO program.
(2) Correcting these illegal arguments.
(3) Press RESET to clear wrong warning message.
INT 3013:PART PROGRAM HAS GRAMMER ERROR.
(1) Input data has grammar error.
(2) Part program error.
(3) Press RESET to clear wrong warning message.
INT 3050:TOOL DIAMETER IS 0
(1) Modify tool diameter setting.
INT 3051:ILLEGAL RPM GIVEN
(1) Part program command has rotation speed command over maximum setting.
(2) Modify error in part program.
INT 3052:ILLEGAL FEEDRATE GIVEN
(1) Part program command has feed rate command over maximum setting.
(2) Modify error in part program.
LNC-M515i
SYSTEM ALARM (Alarm)and WARNING(Warning)
216 LNC Technology Co., Ltd.
INT 3053:(D)EACH CUT DOWN DEPTH IS 0
INT 3054